Mastic
No. 50-44 Intumescent Coating for
Structural Steel is an
asbestos free, reinforced, thermal
protective coating, designed for application
to interior structural steel, to increase
fire endurance time to one hour.
Mastic No. 50-44, when applied at
a wet film thickness of 3/16”
(8.55 sq. ft./US gal) – 4.76
mm (0.21 sq. m./L), on W8 x 24 and
W8 x 28 (W200 x 36 and W200 x 42)
structural steel, as prescribed in
ULC design number O600, has been assigned
a fire resistance rating of 1 hour
when fire tested in accordance with
ULC-Can-S101 (similar to ASTM E-119,
UL-263, NFPA-251). Refer to Underwriter’s
Laboratories (ULC) can label data,
and test reports.
The coating dries to a hard, flexible
finish that withstands structural
movement or vibration and does not
dust, flake, spall or crack. Spray
application yields a textured, stucco-like
finish which can be lightly troweled
to a relatively smooth finish. Color,
off white.
Application of Mastic No. 50-44 requires
a heavy duty air driven pump, and
a special gun. See Flame Control product
data sheet for detailed information
on working with No. 50-44.
|